How to Wire a Temperature Switch (Thermostat)?
The wiring of a temperature switch (thermostat) depends on its type and function. Below are universal wiring methods and key considerations:
I. Power Supply Wiring?
Confirm Supply Voltage?
Most thermostats operate on ?220V AC?. Connect power wires to terminals marked "AC 220V," "Power," "L/N," or equivalent (typically terminals 8-9, 2-3, or L/N) 123??.
Wiring Standards?
Line (L) and Neutral (N) wires don’t require strict polarity but must be securely fastened ?.
For high-power devices (>1000W), use a ?contactor? for control—the thermostat only provides a control signal ??.
II. Output Control Wiring?
1. Relay Output Type?
Controlling Heating Devices?:
Connect ?Normally Open (NO) contacts? (e.g., terminals 7-8, 12-13) in series with the contactor coil circuit 3??.
Contacts ?close? to start heating when temperature falls below the setpoint; ?open? when temperature is reached 23.
Alarm Function?:
Alarm terminals (e.g., 10-11, 4-5) are typically ?NO contacts? that ?close? during overtemperature to activate alarms 3?.
2. Solid-State Relay (SSR) Control Type?
Output terminals? (e.g., 12-13) require polarity:
Terminal 12 → SSR positive (+)
Terminal 13 → SSR negative (–) 23.
The thermostat outputs a ?DC voltage signal? to drive the SSR 3.
For direct control of low-power devices, connect the output in series with the load and power supply ?.
III. Temperature Sensor Wiring?
Thermocouple/RTD Sensors?
Connect 2-wire sensors according to polarity to designated terminals (e.g., 9-10: Terminal 10 → red wire/positive; Terminal 9 → blue wire/negative) 12.
Terminals are labeled "Temp," "Sensor," or equivalent—ensure secure connections to avoid measurement errors 12.
IV. Wiring Precautions?
Power Off?: Always disconnect power before wiring ?.
Power Matching?:
Relay outputs typically support ≤10A load current. Exceeding this requires an external contactor ??.
SSR control must match the drive voltage 3.
Functional Verification?:
After power-up, set temperature values and test whether output contacts activate correctly during heating/cooling 12.
?? Critical Note?: Terminal definitions vary significantly by model. Always consult the device manual or on-body wiring diagram before proceeding 3??.
Key Terminology?:
常開觸點(diǎn) (cháng kāi chù diǎn) → Normally Open (NO) contacts
接觸器 (jiēchù qì) → Contactor
固態(tài)繼電器 (gùtài jìdiànqì) → Solid State Relay (SSR)
復(fù)位 (fùwèi) → Reset
火線/零線 (huǒ xiàn/líng xiàn) → Line (L)/Neutral (N)